Page 44 - 260909_BACnet_Europe-Journal_45
P. 44

Technology  Technik

          Taming Data Chaos in Existing Buildings


          Datenchaos im Gebäudebestand bezwingen






          The BAS Converter as Key to Digitization   a uniform language for all BA systems that is   BACtwin UAK provides the essential
          and the Digital Twin in Technical Building   equally intuitively interpretable by humans and   hierarchical information required for the
          Management with BACnet.           machines.                            development of a Digital Twin, for example,
          Der BAS-Konverter als Schlüssel zur                                    via the Asset Administration Shell (AAS).
          Digitalisierung und zum Digitalen Zwilling   BACtwin and the UAK Converter:    This hierarchical structure forms a digital
          im Technischen Gebäudemanagement mit   A Revolution in Existing Buildings  representation of the physical assets and
          BACnet.                                                                thus enables continuous data consistency
                                            Available to all building operators from October   throughout the entire life cycle of the
          Existing building stock presents enormous  2026, the UAK Converter from ICONAG-  building, as promoted, for example, in the
          challenges for engineers and technical  Leittechnik enables the automatic conversion of   German Facility Management Association
          decision-makers in Building Management.  data  point designations from existing systems   (GEFMA) working group “Building Operations
          Heterogeneous system landscapes, resulting  into the BACtwin UAK. This makes it possible   4.0”.
          from various construction phases, different  to convert the building automation data chaos
          manufacturers, and planners, often lead to  in  heterogeneous existing installations into  Conclusion
          sheer impenetrable data chaos. However, a  structured information. The goal is to make
          uniform data basis is indispensable for efficient  existing buildings digitization-ready without  The UAK Converter in the context of BACtwin is
          operational management, the implementation  extensive reprogramming of the automation  a game-changer for the digitization of existing
          of modern maintenance strategies, and the use  stations. The ICONAG UAK Converter produces  building  stock.  It  eliminates  the  data  chaos  of
          of AI-based optimization tools. This is precisely  a CSV file that can be imported into any  heterogeneous addressing systems and creates
          where ICONAG steps in with a groundbreaking  other system, independent of ICONAG’s own  a uniform, hierarchical, and interpretable data
          solution:  the  User  Addressing  Key  Converter  management and control system B-CON.  basis, e.g., for technical monitoring, maintenance
          (UAK Converter), developed in collaboration with                     management, AI-driven operational optimization,
          Entendix GmbH.                    The Added Value of BACtwin UAK:    or the development of digital twins. A free trial
                                            Foundation for the Digital Twin and AI   conversion of data point lists can be requested
          The Problem of Heterogeneous      Applications                       on the website www.iconag.com.   
          Addressing Systems
                                            Besides a person-independent interpretability
          Every Building Automation System, often grown  of data points within the scope of operational  Der Gebäudebestand stellt Ingenieure und
          historically,  brings  with it  its  own  logic  and  management, the greatest advantage of  Technikentscheider im Technischen Gebäu-
          addressing structure for data points, which  the  BACtwin UAK in existing buildings is the  demanagement (TGM) vor enorme Herausfor-
          usually cannot be interpreted uniformly. This not  establishment of digitization capability. The  derungen. Heterogene Systemlandschaften,
          only  complicates  operational  management  but  converted data point designations are not only  entstanden aus verschiedenen Bauabschnit-
          also  prevents  comprehensive  analysis  and  the  standardized but also semantically enriched.  ten, unterschiedlichen Herstellern und Planern,
          use of modern digitization technologies. Manual  This makes them interpretable for a variety of  führen  oft  zu einem schier undurchdringlichen
          preparation of this data is time-consuming and  further applications:  Datenchaos.  Eine  einheitliche  Datenbasis  ist
                                              T
          error-prone. Thus, important advantages of  ƒ  echnical Monitoring: A consistent data   jedoch unabdingbar für eine effiziente Betriebs-
          BACnet remain unused.               basis enables precise error analyses and   führung, die Umsetzung moderner Wartungs-
                                              early detection of optimization potentials.  strategien und die Nutzung von KI-basierten
          The BACtwin User Addressing Key   ƒ  Maintenance Management: Through the   Optimierungstools.  Genau  hier  setzt  die ICO-
          According to AMEV Recommendation 174  clear assignment of data points to   NAG mit einer wegweisenden Lösung an: dem
                                              aggregates, assemblies, and plants,   Benutzeradressierungssystem-Konverter (BAS-
          The BACtwin User Addressing Key (BACtwin UAK)   maintenance processes can be automated   Konverter), den sie zusammen mit der Entendix
          is based on AMEV Recommendation No. 174.   and made significantly more efficient.  GmbH entwickelt hat.
          This recommendation from the German Working  ƒ  Operational Optimization using AI
          Group for Mechanical and Electrical Engineering   Systems: The structured hierarchy of the   Die Problematik heterogener
          of State and Municipal Administrations (AMEV)   BACtwin UAK – from aggregate to assembly   Adressierungssysteme
          proposes a universally applicable set of rules for   to plant – creates the ideal basis for the use
          the standardized and user-friendly designation of   of Artificial Intelligence. AI algorithms can   Jedes  GA-System,  oft  historisch
          data points in building automation. In particular,   use the interpreted data to optimize   gewachsen, bringt seine eigene Logik und
          the  BACtwin UAK introduces a manufacturer-  operational strategies, reduce energy   Adressierungsstruktur für Datenpunkte mit
          independent and understandable structuring of   consumption, and continuously improve the   sich, die i.d.R. nicht einheitlich interpretiert
          data point addressing, with a structure based   building’s performance.  werden kann. Dies erschwert nicht nur die
          on aggregate, assembly, and plant. This creates  ƒ  Development of a Digital Twin: The   Betriebsführung, sondern verhindert auch


          44  BACnet Europe Journal 45 09/26
   39   40   41   42   43   44   45   46   47   48   49